| Product Range :- 500 Liters./Hr to 20,000 Liters./Hr. |
|
| Sources of Water |
GIECL Treatment Scheme |
| Deep Well Water |
Pretreatment With R.O.System |
| Bore Hole Water |
Pretreatment With R.O.System |
| Open Well Water |
Chlorination, Pretreatment With R.O.System |
| River Water |
Chlorination, R.O.System and Ozonation |
| Lake Water |
Chlorination and Filtration with U.V. & Ozonation |
| Sea Water or Sea Source |
Chlorination, Pretreatment With De-Salination, R.O.System
and Ozonation |
|
| |
| River Water for the Mineral Water Production is not advisable
due to Higher Contamination present. The Below Mentioned Treatment
Scheme and Equipments based on the Above Source of Water |
| |
Pretreatment (Filtration System) |
|
| Raw water will be treated by Pretreatment with |
| Pressure Sand Filter |
Removal of Suspended Impurities, Turbidity |
| Activated Carbon Filter |
Removal of Color, Odour, Residual Chlorine, Organic and Inorganic |
| Softening Unit |
Removal for Hardness of water ( Ca ands Mg ) |
|
| |
| Material Of Construction |
: |
S.S. 316 |
| Mode Of Operation |
: |
Auto & Manual |
| Filtering Media |
: |
Pebbles, Sand, Activated Carbon, Cation Resin |
| Piping & Valves |
: |
S.S. - 316 |
| Accessories |
: |
Flow Meter and Pump |
| Instruments |
: |
Pressure Switches & Gauges |
|
| |
| |
| 6000 Liters per hour mineral water plant complete in s.s. 316 with mineral adding System (R.O.System) |
| |
|
| |
| Pretreatment (Filtration System) |
| Anti Scalent dosing |
: |
For Prevention of Chocking in Membrane |
| MCF |
: |
For Removal of Micron Impurities |
| HPP |
: |
For High Pressure and Flow for feed water |
| R.O. Membranes |
: |
For removal of TDS up to 99% |
| |
|
|
| MCF |
: |
S.S. - 316 with 5 micron Cartridge Filter |
| Pump |
: |
Centrifugal pump, S.S. - 316 |
| Pressure Tube |
: |
FRP or GRP and S.S. - 316 |
| R.O. Elements |
: |
TriSep - USA, Osmonics, DOW |
| Electric Panel |
: |
Auto and Semi Auto Available |
Instrument Panel
Mineral adding system |
: |
Flow Meters and Pr. Gauge
Mineral adding giving different taste and mineral rich water |
|
| |
|
| |
 |
| GIECL 100 % assemble the plant in its Own workshop before dispatch and after its 100 % finish then only disassemble it and then dispatch to client premises |
|
|
| |
|
| 4000 Liters per hour S.S> 316 Spring Water Filtration System for natural Mineral Water Production |
| |
| |
 |
| FRP Mineral Water Plant with S.S. 316 post treatment which is economical solution for Mineral Water industry |
| 3000 Liters per hour FRP. Mineral Water Plant with U.V.System 5,000 Liters per hour Complete S.S. 316 Mineral Water plant with two nos. S.S. 316 storage tank with U.V and Ozonation system |
| |
| |
| |
| 2000 Liters per hour R.O. System Supplied to GHANA |
| |
|
| |
|
2000 Liters per hour complete in S.S. – 316 installed at Tanzania with Cleaning and Flushing System |
| |
|
| 1,000 LPH Mineral Water Processing plant with storage tank and oxygen Generator with Ozonation with U.V.System with Fine Micron filter with S.S. 316 Ozone re-circulation tank and pump |
| |
|
|
|
6000 Liters per hour Latest concept Mineral water plant complete in S.S. – 316 with Mineral Adding System online with Ozonation and U.V.System |
| |
|
| |
 |
After removal the Raw Water TDS from R.O.System product Water
TDS will be very less and can not be use for Drinking Application.
As it need to reconstruction of TDS value by adding additional
Mineral in to the R.O.Treated water by Re-Mineralization. This
Process known as Mineral Adding System. This system contains
the Laboratory Chemical dose in to the R.O.Product water.
This process also possible by adding the Filtered Water from Pretreatment which is known as Blending system. By this
way the water contains Natural Ions and Salts
By this way the water contain Natural Ions and Salts. |
|
| |
| |
| After Re-mineralization or Blending the water will be Store
in Product Water Storage Tank and then it Polished with Absolute
Micron cartridge Filter and then pass through the U.V.System
and Ozonation before Packaging
With this world latest Treatment of Raw Water GIECL assures
the Buyer that such Treated Water will be match with any Standards
of Drinking Water. |
| |
| |
| Above Treatment Scheme and Material of equipments also available
in Fiber Glass Reinforced Plastic-FRP |
|
| |
|
|
| GIECL - Model |
Material of Construction |
Treatment Schemes |
| 500 LPH |
S.S. - 316 / FRP |
Pretreatment, R.O.System, Tanks |
| 1000 LPH |
S.S. - 316 / FRP |
Pretreatment, R.O.System, Tanks, Ozone |
| 2000 LPH |
S.S. - 316 / FRP |
Pretreatment, R.O.System, Tanks, Ozone |
| 2500 LPH |
S.S. - 316 / FRP |
Pretreatment, R.O.System, Tanks, Ozone |
| 2500 FIL |
S.S. - 316 / FRP |
Chlorination, Filtration, Tanks, U.V, Ozone |
| 5000 LPH |
S.S. - 316 / FRP |
Pretreatment, R.O.System, Tanks, Ozone |
| 10000 LPH |
S.S. - 316 / FRP |
Pretreatment, R.O.System, Tanks, Ozone |
| 10,000 Spring |
S.S. - 316 / FRP |
Chlorination, Filtration, Tanks, U.V, Ozone |
|
| |
| |
| Reverse Osmosis System (R.O.System) |
| |
 |
| |
| Pretreatment (Filtration System) |
| Anti Scalent dosing |
For Prevention of Chocking in Membrane |
| MCF |
For Removal of Micron Impurities |
| HPP |
For High Pressure and Flow for feed water |
| R.O. Membranes |
For removal of TDS up to 99% |
|
| |
| MCF |
S.S. - 316 with 5 micron Cartridge Filter |
| Pump |
Centrifugal pump, S.S. - 316 |
| Pressure Tube |
FRP or GRP and S.S. - 316 |
| R.O. Elements |
TriSep - USA, Osmonics, DOW |
| Electric Panel |
Auto and Semi Auto Available |
| Instrument Panel |
Flow Meters and Pr. Gauge |
|
| |
| |
|
| Ultra Filtration Plant for Bottled Water Project |
| |
| |
|
| 2000 Liters per hour S.S. Mineral Water Plant with U.V.System
5,000 Liters per hour Complete S.S. 316 Mineral Water plant with
two nos. S.S. 316 storage tank with U.V and Ozonation system |
| |
| |
|
| 4000 Liters per hour S.S > 316 Spring Water Filtration System
for natural Mineral Water Production |
| |
|
3,000 LPH Mineral Water Processing plant with storage tank and
oxygen Generator with Ozonation with U.V.System with Fine Micron
filter with S.S. 316 Ozone re-circulation tank and pump |
| |
| |
| |